R-KF2 Kemfast Polyester Resin
Performance Data
|
SIZE
|
IN
CONCRETE 30 N/mm2
|
|
SAFE
WORKING LOAD (kN)
|
FAILURE
LOAD (kN)
|
NORMAL
EDGE DISTANCE (mm)
|
NORMAL
SPACING (mm)
|
|
Tension
|
Shear
|
Tension
|
Shear
|
Tension
|
Shear
|
Tension
& Shear
|
|
M10
|
4.2
|
4.6
|
20.8
|
13.9
|
70
|
90
|
90
|
|
M16
|
11.2
|
12.6
|
56.0
|
37.7
|
90
|
130
|
130
|
|
M20
|
13.3
|
19.6
|
66.5
|
58.8
|
110
|
150
|
150
|
R-KEA Epoxy AcrylateResin System
Performance Data
|
SIZE
|
IN
CONCRETE 30 N/mm2
|
|
SAFE
WORKING LOAD (kN)
|
FAILURE
LOAD (kN)
|
NORMAL
EDGE DISTANCE (mm)
|
NORMAL
SPACING (mm)
|
|
Tension
|
Shear
|
Tension
|
Shear
|
Tension
|
Shear
|
Tension
& Shear
|
|
M10
|
6.0
|
6.0
|
27.1
|
18.1
|
90
|
130
|
130
|
|
M16
|
13.4
|
16.3
|
60.5
|
49.0
|
130
|
170
|
170
|
|
M20
|
17.8
|
25.4
|
80.3
|
76.2
|
150
|
190
|
220
|
Installation Procedure
- Drill hole to
correct diameter and depth for size of stud to be used then thoroughly
clean hole using brush or air.
- Fit sleeve for
hollow blockwork and brickwork (if necessary).
- Remove plastic
end cap and red plug. Insert cartridge into gun and attach nozzle.
Dispense to waste until an even colour and pump into hole.
·
Insert stud or socket with a twisting
action. Leave the anchor undisturbed until the resin has set then attach
fixture.
Important Note
To the best of our knowledge and belief, the information contained in
this leaflet is true and accurate, but as conditions of use and any labour
involved are beyond our control, it is the responsibility of the customer
to satisfy himself that this product is fit for the purpose for which he
intends to use it, and no responsibility can be accepted, or warranty given
by our company.
|